Difference between revisions of "Flashing Failed/ru"
From Spirit System Manual
(Updating to match new version of source page) |
(Updating to match new version of source page) |
||
Line 32: | Line 32: | ||
:#Choose correct COM port in the Connection tab first. | :#Choose correct COM port in the Connection tab first. | ||
:#Go to the Update tab and select firmware you want to flash. | :#Go to the Update tab and select firmware you want to flash. | ||
− | :#Power up the unit (from your BEC or a battery). | + | :#Press the Flash button and confirm - software will download firmware from Spirit Server. |
− | + | :#Power up the unit (from your BEC or a battery) when you see 0% progress bar. Immediately after power up flashing should start. | |
:#In 10 seconds, unit should be operating again without any issue. Your settings are untouched. | :#In 10 seconds, unit should be operating again without any issue. Your settings are untouched. | ||
Revision as of 13:25, 25 May 2022
1 Модуль не работает после обновления прошивки
В случае, если модуль не работает после обновления прошивки, используйте данное руководство для восстановления его работоспособности.
Главные вопрос, почему был сбой ?
- Возможные причины:
- Неустойчивое соединение между ПК и модулем Spirit ( проверьте все кабели )
- Bad USB interface driver in your Operating System.
Если проблема наблюдается под Windows, переустановите программу настройки и драйвер.Это установит правильный драйвер. Перезагрузитесь.
Если проблема наблюдается под Mac, используйте драйвер: OSX 11.0 Big Sur
Другие драйвера почти точно будут работать неправильно - особенно во время прошивки!
- Requirements for the Recovery process:
- Правильный установленный драйвер
- Status LED of the unit must be pulsating after power up.
2 Как оживить модуль
- Подключите модуль к ПК по USB ( порт SYS ) (SYS port).
- Start the software. Select Recovery mode when prompted.
- Choose correct COM port in the Connection tab first.
- Go to the Update tab and select firmware you want to flash.
- Press the Flash button and confirm - software will download firmware from Spirit Server.
- Power up the unit (from your BEC or a battery) when you see 0% progress bar. Immediately after power up flashing should start.
- In 10 seconds, unit should be operating again without any issue. Your settings are untouched.