− | === 2x | + | === 2x bliknutí === |
Pressure sensor is not operating correctly. Usually this problem occur when GeoLink is operated for prolonged time under extremely high humidity conditions. | Pressure sensor is not operating correctly. Usually this problem occur when GeoLink is operated for prolonged time under extremely high humidity conditions. |
Revision as of 09:12, 2 August 2018
V případě, že se vyskytne porucha modulu, je pilot informován stavovou LED. Jakýkoli chybový stav je signalizován periodickým blikáním stavové LED. Pokud se objeví chyba např. po havárii modelu, pak je nezbytná jeho oprava.
Blikání stavové LED se v případě poruchy objeví ihned po připojení napájení. Počtem probliknutí ihned za sebou lze určit o jakou chybu se jedná.
Contents
1 Poruchy
1.1 1x bliknutí
Uložené data o hardware modulu byla ztracena. Je nezbytné kontaktovat výrobce.
1.2 2x bliknutí
Pressure sensor is not operating correctly. Usually this problem occur when GeoLink is operated for prolonged time under extremely high humidity conditions. Store GeoLink in low humidity environment for few hours until internal condensate will evaporate. If this will not help contact Spirit System support.
1.3 3x blink
Gyro, accelerometer sensors are not operating correctly. Contacting Spirit System support is necessary.
1.4 4x blink
Compass sensor is not operating correctly. Contacting Spirit System support is necessary.
1.5 Constant blinking
This might happen rather in-flight and could signalize unexpected failure. Most probable reason is shock by high electrostatic discharge. Alternatively it could mean error during Flight Log saving if the problem is repeating. Clearing all Flight Logs could help. Contacting Spirit System support is highly recommended.
2 Other notifications
In case that GeoLink is flashing and pilot can't access it through Spirit Settings then the following can be the reason.
2.1 Calibration process
If you can see 3 series of fast flashing (followed by fast erratic blinks) after power up of the GeoLink then the module is in so called Calibration process. This process can be invoked by pilot through Spirit Settings and must be finished according instructions. Until finished the GeoLink will be inoperable.